Fluke 830 - Laser Shaft Alignment Tool Single laser measurement technology means reduced errors from backlash resulting in better data accuracy
Intuitive guided user interface quickly and easily complete machine alignments Compass measurement mode enables flexible, reliable and repeatable measurements using an activated electronic inclinometer
The Fluke 830 Laser Shaft Alignment Tool is the ideal test tool to precision-align rotating shafts in your facility.
It's a known fact - all rotating machinery is susceptible to misalignment. If you're still using rulers and dial indicators to ensure your rotating machinery is properly aligned, you could be losing thousands of dollars per year in replacement bearing costs, hours of unnecessary repair time, and crippling unplanned downtime, not to mention taking years off your machine's useful life.
The Fluke 830 Laser Shaft Alignment tool is easy-to-use, giving you fast, accurate and actionable answers that will keep your plant up and running. When it comes to laser shaft alignment, data is good but answers are better.
The chain-type bracket fits onto shafts and couplings ranging from 15 to 200 mm (1/2” to 8”) in diameter. [Note that the brackets themselves cover the full range of diameters; it is only the chain lengths that limit.]
All-in-One
Unlike using the straightedge method or dial indicators the Fluke 830 performs the complicated alignment calculations for you, meaning you'll have the answers you need to quickly align your machine and get your plant up and running fast. An enhanced user interface provides easy to understand results that don't require extensive alignment knowledge and the unique "All-in-One" result screen that shows you both coupling results and feet corrections (vertical and horizontal) in real terms making it easy to take corrective action.
Since machine downtime is costly, test repeatability is critical. The Fluke 830 uses a patented single laser precision alignment system that provides accurate and repeatable measurement results so you can be assured you're addressing misalignment problems properly. Evaluate alignment in 3 simple steps The new Fluke 810 helps you locate and diagnose common mechanical problems and prioritize repair actions in three simple steps: 1. Setup
Step-by-step input of the machine dimensions. 2. Measure
Rotate the shaft and receive instant measurement verification. 3. Diagnose
Actual correction numbers are given along with a 4-level color severity scale indicating whether your machine is misaligned Handling gross misalignment
When machines are well outside of accepted tolerances it can be difficult to get accurate alignment readings. For these gross mis-alignment problems the Fluke 830 uses a unique “Extend” mode allowing for better measurement accuracy by automatically increasing the effective sensor measurement area. Increasing the sensor measurement area virtually allows the Fluke 830 to address gross misalignment quickly without the need to perform an initial rough alignment. Additional features and benefits: Clock mode for vertical & flanged machines Machine Flip to flip image of machine on screen for alignment jobs with obstructions Resume mode to save your work and return back at the same step (anytime you need) Fluke predictive maintenance tools help keep your plant up and running
Fluke offers a complete line of predictive maintenance tools designed to help keep your plant up and running. Whether you’re using a Fluke vibration tester to diagnose fault and severity, or a Fluke infrared camera to evaluate machine health, Fluke predictive maintenance tools are designed to give you the answers you need to reduce unplanned downtime and decrease repair costs. The Fluke 830 Laser Shaft Alignment Tool uses a similar measurement process as the Fluke 810 Vibration Tester making laser shaft alignment as easy as 1-2-3. Just set up the unit, perform the test, and evaluate the diagnosis.
Using a Fluke infrared camera you can quickly identify possible machine health problems, and then use a Fluke vibration tester to further diagnose the problem and determine whether or not mis-alignment is present. Using the Fluke 830 Laser Shaft Alignment tool you can get the answers you need to correct misalignment, and then further verify your results with your Fluke infrared camera or vibration tester to check the machine health.
In The Box Laser Sensor Laser Prism Chain-type mounting bracket with 150 mm support posts (2x) 300 mm support post (4x) Micro Fiber Cleaning Cloth Sensor Cable PC Cable USB Drive USB Drive Cable Tape Measure Wireless Bluetooth Module Instruction Kit Carrying Case NO POWER ADAPTER $330 FROM FLUKE
NOTE: Calibration certificate is not included and not available for the 830
Manuals/Guides Manuals Spec Sheets Application Notes Other
Manufacturer Specs Fluke 830 Technical Specifications Computer CPU Intel XScale PXA270 running at 312 MHz Memory 64 MB RAM, 64 MB flash Display Type: TFT, transmissive (sunlight-readable), 65,535 colors, backlit LED Integrated light sensor for automated adjustment of the brightness to the display according to the lighting conditions which extends battery life Resolution: 320 x 240 pixel; Dimensions: 89 mm (3.5 in) diagonal Keyboard elements: Setup, measure, diagnose, menu, clear, enter, back keys, navigation cursor cross, alphanumeric key- board and on/off button LED indicators Multicolor LED for laser status and alignment condition Multicolor LED for battery status Power supply Integrated Lithium-ion polymer rechargeable battery: 7.4 V/ 2.6 Ah (for optional computer) with typical operating time of 17 hours (based upon an operating cycle of 33 % measurement, 33 % computation and 33 % ‘sleep’ mode) External interface USB host and USB device (slave) Integrated wireless communication, Class 1, transmitting power 100 mW RS232 (serial) for sensor AC adapter/charger socket Environmental protection IP 65 (dustproof and water spray resistant), shockproof Relative humidity 10 % to 90 % Operating temperature -10 °C to 50 °C (14 °F to 122 °F) Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) Dimensions 220 mm x 165 mm x 45 mm (8.7 in x 6.5 in x 1.8 in) Weight 742 g (1.64 lb) Sensor Measurement principle Coaxial, reflected laser beam Environmental protection IP 67 (submersible, dustproof) Ambient light protection Yes Storage temperature -20 °C to 80 °C (-4 °F to 176 °F) Operating temperature 0 °C to 55 °C (32 °F to 131 °F) Dimensions 107 mm x 70 mm x 49 mm (4 1/4 in x 2 3/4 in x 2 in) Weight 177 g (6 1/2 oz) Laser Type: Ga-Al-As semiconductor laser Wavelength (typical) 675 nm (red, visible) Safety class: Class 2, FDA 21 CFR 1000 and 1040 Beam power: < 1 mW Safety precautions: Do not look into laser beam Detector Measurement area: unlimited, dynamically extendible (U.S. Patent 6,040,903) Resolution: 1 m; Accuracy (avg): > 98 % Inclinometer Measurement range: 0° to 360°; Resolution: <1° Prism Type 90° roof prism; Accuracy (avg): > 99 % Environmental protection IP 67 (submersible, dustproof) Operating temperature -20 °C to 60 °C (-4 °F to 140 °F) Storage temperature -20 °C to 80 °C (-4 °F to 176 °F) Dimensions 100 mm x 41 mm x 35 mm (4 in x 1 5/8 in x 1 3/8 in) Weight 65 g (2 1/2 oz.) Carrying case Dimensions 565 mm x 343 mm x 127 mm (22 1/4 in x 13 1/2 in x 5 in) Weight, including all standard parts 5.6 kg (12.3 lb)
Tech Specs
Test Equipment General Attributes Interfaces I/O RS-232, USB Host, USB Product Weight 1.64 LBS Product Height 8.7 IN Product Length 6.5 IN Product Width 1.8 IN Battery Type Li-ion Power Supply Voltage Battery Powered Country of Origin Germany Shipping Height 5.50 IN Shipping Length 22.25 IN Shipping Width 14.95 IN